ENHANCED ARS FOR NEEDLE DECOMPRESSION
SKU:
$20.00
18.2
20
$18.20 - $20.00
Unavailable
per item
- Features an improved needle tip design with “scalpel” sharp, bi-bevel, tapered needle tip, which improves penetration control through tissue of varied type and thickness.
- The new fenestrated catheter delivers statistically significant improvement for tension relief and the prevention of distal catheter occlusion when compared to traditional non-fenestrated catheters. The three fenestrations, combined with the catheter tip, deliver four paths for air to escape.
- Centimeter graduated catheter for safer placement utilizing “thoracic depth control”. Evidence and anecdotal experiences continue to strongly suggest the need for insertion CONTROL with needle decompression.
- The flexible catheter is designed to decrease incidence of catheter kinking.
DESCRIPTION
Acting on evidence-based medicine, NAR is introducing the Enhanced ARS™ (Air Release System) as an additional offering in their needle decompression product line. The Enhanced ARS™ brings several features specifically implemented to address needs identified in the data.
The new fenestrated catheter delivers statistically significant improvement for tension relief and the prevention of distal catheter occlusion when compared to traditional non-fenestrated catheters. The three fenestrations, combined with the catheter tip, deliver four paths for air to escape.
This exponentially decreases the potential for blockage that would interfere with airflow. During investigative research, fenestrated catheters were additionally shown to offer faster pressure relief and succeed when non-fenestrated catheters failed.
Centimeter graduated catheter for safer placement utilizing “thoracic depth control”. Evidence and anecdotal experiences continue to strongly suggest the need for insertion CONTROL with needle decompression.
Learning Point: Average depth from exterior of targeted RIB to parietal pleura is 0.5 - 1 cm. Centimeter markings allow for PRECISE placement just beyond the parietal pleura AND help clinicians PREVENT OVER INSERTION!
This exponentially decreases the potential for blockage that would interfere with airflow. During investigative research, fenestrated catheters were additionally shown to offer faster pressure relief and succeed when non-fenestrated catheters failed.
Centimeter graduated catheter for safer placement utilizing “thoracic depth control”. Evidence and anecdotal experiences continue to strongly suggest the need for insertion CONTROL with needle decompression.
Learning Point: Average depth from exterior of targeted RIB to parietal pleura is 0.5 - 1 cm. Centimeter markings allow for PRECISE placement just beyond the parietal pleura AND help clinicians PREVENT OVER INSERTION!